<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-20 22-32-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 56 dBuV NOSTALGI
Pilot RDS Phase Difference
6.2 kHz 4.2 kHz 80 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 70 kHz 19080 0,0314
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
5,4 dBr 6,07 dBr 6,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Barry Manilow - Mandy "
AF EON
89.7, 90.9, 92.7, 94.3, 98.4, 99.5 MHz -
FM Scope Max at: 70 kHz MIN: 10 kHz % above 76 kHz: 0,0314 Acquired: 2026/01/20 22.31.16 Total samples: 19080 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000 4000
FM Scope MAX: 6,7 dBr MIN: 5,4 dBr AVE: 6,07 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2026/01/20 22.31.15) 22.18 22.20 22.22 22.24 22.26 22.28 22.30 0 2 4 6 Pm [dBr]